The Agasthya 2013 Series Continuous Emission Monitoring System BI 7000 is designed in compliance with emission norms to measure gas pollutants emitted by various process industry and to meet the needs of industries requiring cost effective and reliable multiple gas analyzer solutions.

BI7000 is TUV certified for CE mark & Performance as per EN15267 standard.

The technology employed are of maximum reliability and accuracy to ensure high degree of performance & long life.

BI7000 is ideal solution to protect initial investment & can adapt to any process application with modular design & can house up to eight gas sensors with scalable ranges for each gas. Manufactured for use in hostile or friendly environments the BI 7000 Continuous Emission Monitoring System maintains high levels of gas selectivity. All packed into a robust, attractive, industrial enclosure.

Features :

  • Tried and tested technology with proven reliability
  • Wide range of gas selectivity & scalable ranges available for each gas
  • 5.7” TFT Keypad Display
  • The best price performance on the market – designed with user requirements foremost in mind
  • Isolated 4-20 mA analog output for each gas
  • RS 485, supports MODBUS protocol
  • High / Low Gas, low flow & other programmable events available
  • Highly efficient automatic purge & drain system
  • Inbuilt interface for Remote Calibration Unit
  • Auto & semi auto calibration facilities

Specification :

Parameter Resolution Accuracy Scalable Range
NDIR (Non Dispersive Infrared)
Carbon Monoxide 1 ppm ±1% FSD 0-5000 ppm
Nitric Oxide 1 ppm ±1% FSD 0-1000 ppm
Sulphur Dioxide 1 ppm ±1% FSD 0-1000 ppm
Carbon Dioxide 0.1% ±1% FSD 0-20%
Hydrocarbon 0.1% ±1% FSD 0-5%
NDUV (Non Dispersive Ultraviolet)
Nitrogen Dioxide 1 ppm ±1% FSD 0-1000 ppm
Sulphur Dioxide 1 ppm ±1% FSD 0-1000 ppm
Chlorine 1 ppm ±1% FSD 0-30 ppm
Hydrogen Sulphide 1 ppm ±1% FSD 0-50 ppm
TDLS (Tunable Diode Laser Spectrometry)
Hydrogen Flouride 1 ppm ±1% FSD 0-30 ppm
Hydrogen Chloride 1 ppm ±1% FSD 0-200 ppm
Ammonia 1 ppm ±1% FSD 0-500 ppm
Hydrogen Sulphide 1 ppm ±1% FSD 0-200 ppm
Zirconia
Oxygen 0.1% ±1% FSD 0-30%
FID (Flame Ionization Diode)
HC 1 ppm ±1% FSD 0-1000 ppm

Analyzer Specification :

Repeatability 1% FS
Zero Drift <±1% per week of Span
Span Drift <±1% per week of Span
Response T90 <15 sec
Operating Temperature 4°C to 65°C
Analog output Isolated and linear 4-20mA analog output for each gas
Digital Communication RS 485, Supports MODBUS Protocol
Relay Output 2 Nos. Potential free contact for alarms
Power Supply 110/230 VAC, 50 Hz
Programmable events for High / Low Alarms
Auto & semi auto calibration facilities

System Components :

Heated Sampling Probe
Operating temperature Max. 400ºC
Mounting Flange Type
Max. working pressure 6 bar
Voltage 110/230 V, 50 /60 Hz
Heating Self-regulating +180ºC
Ambient temperature -20 to +80ºC
For dust concentration Upto 5 g/m³
MOC SS 316
Heated Sample Gas Line
Process Tube PTFE / SS
Process Tube Size 1/4 inch OD
Heating Element Constant watt type
Thermal Insulation Non – Hygroscopic Fiber Glass
Outer Sheath Extruded UV Resistant FRLS PVC
Operating Voltage 230 V AC
Watt Density 45 W/m
Length To be specified by client
Max. Operating Temperature 200ºC
Temperature Sensor In built RTD
Process Connection Flanged Type
Power/Control Connection Lead cable (3 Wire), 2 Meter for both power & control

Sample Conditioning Unit

Smart unit

  • Aspirator/Pump for sampling flue gas
  • Pre and post cooler fine filters to remove drain, dust and mist in sample gas
  • Auto drain and auto purging (blow back) facilities
  • 2 way solenoid valves for switching, sampling, purging, draining and calibration
  • Flowmeter to regulate and monitor the flow of sample gas
  • Drain pump for continuous removal of condensate

NOx Converter :

High NO2 Conversion Capability
Enclosure 19 inch Housing
Working temperature 400ºC
Sample gas pressure up to 1.5 bar
Warm-up time 30 min
Sample gas flow up to 120 l/h
Sample gas temperature 5 to 80ºC
Ambient temperature 5 to 50ºC
Connection 1/4″f NPT.
Materials SS316, PTFE, Viton

Cabinet

Smart unit

  • Industrial Cabinet
  • Meets IP 54 standard
  • Inbuilt air conditioning system
  • Automatic cabinet illumination when door open
  • Earthing bar assembly
  • 180 degree door opening
  • Standard Dimension: 1500 (H) x 600 (W) x 800(D) mm
  • ** Purge Panel available on request for Hazardous Area.

Remote Calibration System

  • Panel with certified cylinders and automation for calibration
  • Software with User Interface for remote calibration
  • Compatible to interface with any Server

Server Data Connectivity to CPCB & SPCB available